• Door and Card Access Integration

    Track all building entrances and exits and automatically activate cameras and notify administrators when doors are held or forced open.

    PRODUCT OVERVIEW

     

    • Receive visual notifications when doors are held or forced open.
    • Protect your people and property with restricted access and security camera surveillance.

     

    PRODUCT FEATURES

     

    • Monitor all entrances and exits from your desktop or mobile app.
    • Lock all doors using contact closures.
    • Automatically push to public address to announce ‘door held open.’
    • Integrates with security cameras.
    • Automatically push live camera views to admin and security when doors are forced open.
    • Software interfaces with security cameras, phones, mobile apps, pagers and audio public address and is easily activated in case of an emergency.

     

    PRODUCT BENEFITS

     

    • Easily deny or restrict access to entire buildings, hallways or rooms.
    • Eliminate or reduce the need for security officers at all entrances and exits.
    • Add a layer of safety and security for front desk employees.
  •  

    REQUIREMENTS

     

    The integration can be completed either by using an Ethernet to RS232 device for any event or contact closure for individual events.

     

    Software

     

    • Door/Card Access Integration Module
    • Tier 3 License per RS232 connection or Tier 2 License per Contact Closure port

     

    Equipment

     

    Server Platform - one of the following components:

    • Small Intel Server: Model-NUC Small Form Factor (LSI-H10200)
    • Dell Server: Dual Power, Hardware RAID (LSI-H10302)*
    • Virtual Server: Requires client to provide virtual environment and network/tech support
    • Customer Provided Server: Minimum server requirements*
    • One of the following components:
      • Single Port Ethernet to RS232 Adapter – Standard Power (LSI-H18501) or PoE (LSI-18502)
      • Contact Closure Device - IPIO2, IPOI8 or IPIO16 (LSI-H18602, LSI-H18601, LSI-H18616)

    Network

     

    • Server
      • 1 static IP, subnet, gateway, DNS, per device
        • 3 static IPs, subnet, gateway, DNS, per device if using a redundant configuration
      • Standard power (110V or 220V) per server
      • Ethernet network connection required for each server
      • UPS recommended
      • It is the responsibility of the customer to appropriately configure their network equipment so that the server pair appears to be residing on the same network and subnet.
      • NOTE: Serial and parallel ports have been disabled on the LSI server

     

    Single Port Ethernet to RS232 Adapter (LSI-H18501/LSI-H18502)

     

    • 1 static IP per device, subnet, gateway, DNS per device
    • Baud rate, parity, stop bit(s), data bits of RS232 connection
    • POE or standard power option
    • Ethernet network connection
    • Uses null-modem adapter (provided by LSI)

     

    Contact Closure Integration (LSI-H13601/LSI-H13602/LSI-H13616)

     

    • 1 static IP, subnet, gateway, DNS per device
    • Standard power per device
    • Ethernet network connection
    • Includes mounting bracket
    • NOTE: Connection to the contacted device is limited to 100 ft. using 18- or 20-gauge wire.

    * optional redundant configuration

     